Getting a Heat Pump Ready for a Baldwin County Cold Snap
The Eastern Shore spends so much of the year trying to get heat out of the house that January feels like a rumor. Then a front clears the rain, the night drops into the 30s, and every heat pump that has not been asked to heat since last winter gets a live test. Some pass. The ones with a dead sequencer, a thermostat that never calls for auxiliary heat, or a defrost board that does nothing become the calls.
NOAA’s normals for Mobile Regional Airport, the long-record station for this bay, put January’s average low at 40.7°F and count about 21 days a year with a minimum at or below freezing. Heating degree days for the year are 1,616, against 2,599 cooling degree days. The heating season is short. It is not optional. A house in Silverhill or Loxley on a clear night can feel colder than a bayfront house, because the water is not sitting there moderating the air. Point Clear and the Fairhope bluff still get the damp cold that ices coils.
Defrost is the whole plot
A heat pump coil frosts when it is heating in damp air. That is expected. The defrost cycle should reverse the system, melt the ice, and let the outdoor fan do its job again. While that happens, backup heat inside the house should run so you are not pouring cool air into bedrooms.
Ice that never melts, a unit that ices in weather that is only cool, or a house that gets colder the longer the heat runs, means defrost or charge or strips. Turn the system off if the outdoor unit is a block of ice. Heat pump repair is the visit. Do not leave it roaring under a shell of ice because the thermostat still says heat.
Strips and furnaces, tested on a mild day
Electric strips sit in the air handler and do nothing for ten months. They fail by burning an element or a sequencer, and nobody notices until the one night they are needed. A thermostat can also be configured so it never asks for them, or so it asks for them all the time and the power bill arrives as a shock. Fall is when you find out which.
Gas furnaces have their own idle-season failures, covered on the heating and furnace repair page. If you have gas, the fall check is a firing cycle, not a heat-pump defrost test. Know which machine is in the closet before you book. A photo settles it.
HVAC maintenance in October or November is the appointment built for this. The cooling coil and the drain still get a look, because the next season is never far away on this bay. The heat test is the part people skip, and it is the part that changes a cold night into a non-event.
What you can do without tools
Replace the filter so the first long heating cycle is not done through a brick. Make sure supply vents in the rooms you care about are open. Set the thermostat to heat and a setpoint you can actually reach, and listen. Warm air and a house that catches the setpoint is a pass. Cool air, a burning smell that does not clear in a minute or two, a breaker trip, or an outdoor unit icing over is a stop. Call and describe which of those you heard.
The same outdoor unit will be cooling again by April. Getting the heat side through January does not fix a pitted coil or a system that cannot dry the house. It does keep the cold snap from being the way you discover the strips have been dead since last year.
Questions
How cold does it actually get here?
Mobile's 1991-2020 normals put the January low at 40.7°F, with about 21 days a year when the temperature reaches freezing at that station. That is not a northern winter. It is enough to ice a heat pump coil and enough to make a dead heat strip obvious in a Daphne house.
What should run when the heat pump goes into defrost?
The system briefly reverses to melt the outdoor coil, and the backup heat should come on so the house does not get a blast of cool air the whole time. If the strips or the furnace never come on, the house drops while the outdoor unit thaws. That backup heat is the thing to test in the fall.
Is a gas furnace easier to forget than a heat pump?
Yes, because it may not have fired since early spring. Flame sensors foul, igniters crack, and condensate traps on high-efficiency furnaces clog. A fall firing cycle finds those while the weather is still mild. The heat pump's equivalent is a shift into heat mode plus a call for the strips.